General Purpose Raman Probes

$0.00

High Signal Collection and Effective Filtering Design

Availability:
View Product Models
Item Excitation Wavelength Fiber Connectors Safety Shutter
RIP-RPB-532-SS 532 nm SMA 905 excitation and collection Yes
RIP-RPB-532-FC 532 nm FC excitation and SMA 905 collection Yes
RIP-RPB-638-FC 638 nm FC excitation and SMA 905 collection Yes
RIP-RPB-638-SMA-SMA 638 nm SMA 905 excitation and collection Yes
RIP-RPB-785-SMA-SMA 785 nm SMA 905 excitation and collection Yes
RIP-RPB-785-FC-FC 785 nm FC excitation and collection Yes
RIP-RPB-785-FC-SMA 785 nm FC excitation and SMA 905 collection Yes
RIP-RPB-785-SMA-FC 785 nm SMA 905 excitation and FC collection Yes
RIP-RPB-1064-FC 1064 nm FC excitation and SMA 905 collection Yes
RIP-RPB-1064-SMA-SMA 1064 nm SMA 905 excitation and collection Yes
RIP-RPS-532 532 nm FC (standard) or SMA 905 No
RIP-RPS-785 785 nm FC (standard) or SMA 905 No

RPB and RPS general purpose Raman probes are available in additional excitation wavelengths, connector combinations and assembly lengths. Contact an Ocean Optics Applications Scientist for details.

Out of stock

Our RPB and RPS Raman probes are versatile sampling accessories for lab applications. The probes are available for 532, 638, 785 and 1064 nm with FC and SMA 905 connectors for excitation and collection fibers. RPB probes are anodized aluminum with a stainless steel tip and include a manual safety shutter; RPS probes are stainless steel and include an emission indicator. These are non-immersion probes that are ideal for measurement of solids and surfaces and for measurement through glass and plastics.

  • Versatile – options for wide range of Raman spectroscopy laboratory applications
  • High performance – strong signal collection and high OD laser line filtering
  • Safety shutter options – RPB series probes include manual safety shutter
  • Deep laser line blocking – OD 6-8 attenuation of the Rayleigh line, depending on part number

Engineering Specifications RPB Probes RPS Probes
Excitation wavelengths: 532, 638, 785 and 1064 nm (standard) 532 nm and 785 nm (standard)
Spectral range:* 300 – 3900 cm-1  250 – 3900 cm-1 
Laser line blocking: OD 6 OD 8
Sampling head: Anodized aluminum Stainless steel
Probe length: 107 mm 76 mm
Probe diameter: 9.5 mm 9.5 mm
Working distance: 7.5 mm (standard) 5.0 mm (standard)
Fiber configuration: Excitation and collection fibers; 0.22 NA Excitation and collection fibers; 0.22 NA
Fiber length: 1.5 m 5 m
Fiber connectors: FC (standard) and SMA 905 FC (standard) and SMA 905
Built-in safety shutter: Yes No

*Ultimate spectral range depends on detection range of the spectrometer, and may be more limited

Measurement Techniques in which this product is used: