QE Pro-FL

$15,278.00

High-sensitivity Spectrometer for Fluorescence

Availability:
The most sensitive spectrometer

The QE Pro-FL is ideal for low light level applications such as fluorescence. This robust spectrometer has back-thinned, TE-cooled CCD detector and is preconfigured for fluorescence measurements from 350-1100 nm. The QE Pro-FL’s dynamic range performance ranks it among the highest sensitivity miniature spectrometers available today. This is especially significant for applications such as fluorescence, where signals may be weak and minimum detectable sample limits are often challenging.

  • Portable – small footprint, light weight, fiber optic based spectrometer for the field
  • Sensitive – high quantum efficiency detector
  • Powerful – signal-to-noise ratio of >1000:1
  • Stable – cooled detector allows low light detection and prevents spectral distortion

Engineering Specifications QE Pro-FL
PHYSICAL
Dimensions: (L x W x H) mm and inches 182 mm (7.17 in.) x 110 mm (4.33 in.) x 47 mm (1.85 in.)
Weight: kg and lb spectrometer: 1.15 kg (2.6 lbs.); power supply: 0.45 kg (1 lb.)
DETECTOR
Type: Hamamatsu scientific grade, back-thinned, TE Cooled, 1044 x 64 element CCD array
Range: 185 – 1100 nm
Quantum efficiency: 90% (peak)
SPECTROSCOPIC
Wavelength range: 350 – 1100 nm
Integration time: 8 ms to 60 minutes
Dynamic range: ~85,000:1
Signal-to-noise ratio: System: 1000:1 (single acquisition)
Grating: 14 gratings available (H1–H14), HC1 grating
Slit: 5, 10, 25, 50, 100 or 200 µm wide slits (or SMA/FC bulkhead with no slit)
Optical resolution: 0.14 – 7.7 nm (Depends on grating and size of entrance aperture)
Stray light: <0.08% at 600 nm; 0.4% at 435 nm
Buffering: 15,000 spectra
Fiber optic connector: SMA 905 and Ocean Optics FC
ELECTRONICS
Power requirement: Supply voltage: 4.5 – 5.5 V
Strobe functions: continuous and single strobe
Interfaces: USB 2.0, 480 Mbps (USB 1.1 compatible); RS-232 (5-wire)
OPERATING CONDITIONS
Operating temperature: 0 °C – 50 °C
Humidity: ≤ 90% noncondensing

QE Pro-FL is a preconfigured spectrometer for fluorescence measurements and includes:

Engineering Specifications QE Pro-FL
PHYSICAL
Dimensions: (L x W x H) mm and inches 182 mm (7.17 in.) x 110 mm (4.33 in.) x 47 mm (1.85 in.)
Weight: kg and lb spectrometer: 1.15 kg (2.6 lbs.); power supply: 0.45 kg (1 lb.)
DETECTOR
Type: Hamamatsu scientific grade, back-thinned, TE Cooled, 1044 x 64 element CCD array
Range: 185 – 1100 nm
Quantum efficiency: 90% (peak)
SPECTROSCOPIC
Wavelength range: 350 – 1100 nm
Integration time: 8 ms to 60 minutes
Dynamic range: ~85,000:1
Signal-to-noise ratio: System: 1000:1 (single acquisition)
Grating: 14 gratings available (H1–H14), HC1 grating
Slit: 5, 10, 25, 50, 100 or 200 µm wide slits (or SMA/FC bulkhead with no slit)
Optical resolution: 0.14 – 7.7 nm (Depends on grating and size of entrance aperture)
Stray light: <0.08% at 600 nm; 0.4% at 435 nm
Buffering: 15,000 spectra
Fiber optic connector: SMA 905 and Ocean Optics FC
ELECTRONICS
Power requirement: Supply voltage: 4.5 – 5.5 V
Strobe functions: continuous and single strobe
Interfaces: USB 2.0, 480 Mbps (USB 1.1 compatible); RS-232 (5-wire)
OPERATING CONDITIONS
Operating temperature: 0 °C – 50 °C
Humidity: ≤ 90% noncondensing