Home > News & Events > Radiometric Light Source and Calibration Upgrades

Radiometric Light Source and Calibration Upgrades

Updated Product Line and Calibration Procedures Add Value

We are pleased to announce updates to our line of radiometrically calibrated lamps and standard light sources that will simplify your product selection process and ensure greater calibration accuracy.

Details on changes affecting our D-2000, DH-2000- and HL-2000 series illumination sources are available here.

 

Light Sources for Spectroscopy Applications 

Ocean Optics offers radiometrically calibrated light sources that are carefully measured and characterized to deliver a known quantity of light with a very low uncertainty. Sources are available that are calibrated for use with a cosine corrector (standard), integrating sphere (with HL-3P sources only), bare fiber (optional) or extended wavelength range (optional).

We’ve now streamlined our calibration source offering and have updated the process for bare fiber calibrations, improving calibration accuracy (see Tech Tip). Here is a summary of the changes:

 

Changes Affecting Radiometrically Calibrated Deuterium-Tungsten Halogen Sources

 

Discontinued Item Category Replacement Items Description
DH-2000-CAL
DH-3-CAL
Deuterium-Tungsten Halogen DH-3P-CAL Radiometrically calibrated deuterium-tungsten halogen light source (200-1100 nm) w/cosine corrector (wide FOV) calibration; add calibration options for bare fiber (-BF) or extended wavelength range (-EXT) separately
DH-2000-CAL-EXT
DH-3-CAL-EXT
DH-3P-CAL-EXT
Deuterium-Tungsten Halogen DH-3P-CAL and
DH-EXT-CAL
DH-3P-CAL w/extended wavelength range calibration (1100-2400 nm)
DH-3-BAL-CAL Balanced Deuterium-Tungsten Halogen DH-3P-BAL-CAL Radiometrically calibrated deuterium-tungsten halogen light source (230-1050 nm) w/balanced spectral output and cosine corrector (wide FOV) calibration; add calibration options for bare fiber (-BF) or extended wavelength range (-EXT) separately
DH-3-BAL-CAL-EXT Balanced Deuterium-Tungsten Halogen DH-3P-BAL-CAL and
DH-EXT-CAL
DH-3P-BAL-CAL w/extended wavelength range calibration (1100-2400 nm)

 

Changes Affecting Tungsten Halogen Sources

 

Discontinued Item Category Replacement Item Description
HL-2000-CAL
HL-2000-HP-CALHL-3-CAL
Tungsten Halogen HL-3P-CAL Radiometrically calibrated tungsten halogen light source (350-1100 nm) w/cosine corrector (wide FOV) calibration; add calibration options for bare fiber (-BF) or extended wavelength range (-EXT) separately
HL-2000-CAL-EXT
HL-3-CAL-EXT
HL-3P-CAL-EXT
Tungsten Halogen HL-3P-CAL and
HL-EXT-CAL
HL-3P-CAL w/extended wavelength range calibration (1100-2400 nm)
HL-2000-CAL-ISP
HL-3-INT-CAL
Tungsten Halogen HL-3P-INT-CAL Radiometrically calibrated tungsten halogen light source (350-1100 nm) designed for use with integrating spheres; add calibration options for bare fiber (-BF) or extended wavelength range (-EXT) separately
HL-3-INT-CAL-EXT
HL-3P-INT-CAL-EXT
Tungsten Halogen HL-3P-INT-CAL and

HL-EXT-CAL

HL-3P-INT-CAL w/extended wavelength range calibration (1100-2400 nm)

 

Recalibration Services for Radiometrically Calibrated Light Sources

Calibrated sources typically provide about 50 hours of operation before requiring recalibration, and are not intended for use as an illuminant in day-to-day measurements. Recalibration service is available.

 

Discontinued Service Replacement Service Description
DH-2000-RECAL
DH-BAL-RECALDH-RECAL
DH-CAL Recalibration service for DH-series calibrated light sources, 200-1100 nm
DH-2000-RECAL-EXT
DH-BAL-EXT-RECAL
DH-EXT-RECAL
DH-EXT-CAL Extended-wavelength range recalibration service for DH-series calibrated light sources, 1100-2400 nm
HL-2000-RECAL
HL-INT-RECAL
HL-RECAL
HL-CAL Recalibration service for HL-series calibrated light sources, 350-1100 nm
HL-EXT-RECAL
HL-INT-EXT-RECAL
HL-EXT-CAL Extended-wavelength range recalibration service for HL-series calibrated light sources, 1100-2400 nm

 

Ordering Process for Radiometrically Calibrated Light Sources

  1. Select a radiometrically calibrated tungsten halogen (350-1100 nm) or deuterium-tungsten halogen (200-1100 nm) light source.
  2. Select the type of radiometric calibration you require. The standard option is calibration with a cosine corrector. Other options are available for bare fiber calibration (-BF) and extended wavelength range calibration (-EXT), which covers 1100-2400 nm.
  3. Consult an Applications Scientist for assistance or with questions on custom calibrations.